Swiss stock · Shipping within Switzerland

Schutzmasken.ch
Cart

Protective masks compared

Compare FFP1, FFP2, FFP3 and Type IIR medical masks by standard, function and fit, without assuming one mask is universally best.

FFP1, FFP2 and FFP3 at a glance

The three FFP classes apply to particle-filtering half masks under EN 149. Differences include filter penetration and total inward leakage. Classification concerns test requirements; use also depends on fit, handling and suitability for the specific application.

FFP1

Standard: EN 149

Particle-filtering half mask with its own filter penetration and leakage requirements.

Check the seal, design and fit according to the manufacturer’s instructions.

FFP2

Standard: EN 149

Particle-filtering half mask with higher class requirements than FFP1.

Design and fit must suit the application and person.

FFP3

Standard: EN 149

Particle-filtering half mask with higher class requirements than FFP2.

A higher class does not replace proper fit or a suitable design.

Type IIR

Standard: EN 14683

Medical face mask with an additional liquid-splash requirement.

Fit and handling follow the product instructions; not an FFP class.

FFP2 or FFP3 – what is the difference?

FFP3 has higher filtration and total inward leakage requirements than FFP2. This does not imply that a higher class is recommended for every application. Application requirements must be established first.

Even within one class, models differ in shape, size and straps. A higher class does not automatically correct a poor fit. Workplace selection and usage requirements must be considered for occupational use. The respirator overview explains these selection factors.

How do respirators differ from medical masks?

For particle-filtering half masks, directing inhaled air through filter material together with a close fit is essential. Medical face masks are a different product family, primarily focused on limiting droplets from exhaled air.

Type IIR under EN 14683 is a medical face mask with an additional liquid-splash resistance requirement. It does not belong in the FFP1–FFP3 sequence. The page Understanding face masks and medical masks explains everyday terminology.

Which standards matter?

EN 149 describes requirements and test methods for particle-filtering half masks. EN 14683 concerns medical face masks. The standards address different product questions; their numbers are not a shared rating scale for all masks.

Read the standard, manufacturer, model and class or type together, including the relevant conformity information and instructions. Assess markings or testing bodies only in relation to the specific model. Further terms are explained in the FAQ on protection classes and markings.

Fit and valves as separate comparison factors

For FFP masks, the seal must sit against the face according to the model instructions. Hair in this area can cause leaks. Fastening and orientation of medical masks also follow the manufacturer’s information, but do not turn them into FFP half masks.

An exhalation valve may reduce exhalation resistance. Whether and how exhaled air is filtered depends on construction. Rather than merely comparing with-valve and valveless models, check whether the design meets application requirements.

Which mask suits which application?

Describe the task, conditions and existing requirements. Then identify the product family and required class or type. Workplace selection follows the responsible assessment; a general industry label is insufficient.

Then compare shape, straps, model documents and quantity. The FAQ on fit and handling helps with general questions. For documents on a specific model, use contact for a specific product enquiry.